INSTALLATION:
	
		- 
			Unscrew the mounting plate and take it off.(Fig.1、Fig.2)
- 
			Drill a hole as shown in Fig 1. Then put into the bolt and fix it with cement.(Fig.3)
- 
			Hanging on the mounting plate and ensure fix it.(Fig.4)
- 
			Installing the machine onto the mounting plate and ensure the safety, than fix it tighten with screws.(Fig.5)
 
	
		CAUTIONS / INSTALLATIONS:
	
		During installation of the unit, please pay special attention to the following points in order to obtain the ultimate efficiency.
	
		- 
			Install on solid place to avoid vibrations when machine is running and also for safety reasons. Unnecessary noise caused by vibration can be prevented.
- 
			AIR CURTAINS are used for indoor purpose.
- 
			Depending on the height to choose the most suitable model. If it is fixed too high, the shut-off distance will be affected and the efficiency will be reduced.
- 
			The air is drawn into the unit and is blown out downwards.
- 
			Several units can be mounted next to each other when wide door opening occur. Under such condition, a narrow space in between 20-40mm is acceptable.
		PRODUCT OUTLINE:
	
		AIR CURTAINS are designed for installation in shops, office buildings, hotels and restaurants doorway. They discharge a curtain of air, which effectively shuts out outside air. Use them to keep out insects, unpleasant smells, and dust where a large number of people pass in and out. These air curtains also prevent air escaping from premise.
	
		CONDITIONS OF USE:
	
		Please DO NOT install the unit under following conditions:
	
		- 
			Do not operate in ambient temperature over 50°C.
- 
			A relative humidity over 95% at room temperature and steamy area.
- 
			Contains oily smoke.
- 
			Nearby materials or gases that may cause explosion.
- 
			Near corrosive gases.
- 
			Nearby any water sprinkler points
- 
			In order to avoid the air deflector be out of shapre, pls dont hold it when taking out the air curtain from carton!